{"id":2955,"date":"2020-04-09T02:00:19","date_gmt":"2020-04-09T06:00:19","guid":{"rendered":"http:\/\/www.nuclearphysicslab.com\/npl\/?page_id=2955"},"modified":"2020-04-09T13:46:13","modified_gmt":"2020-04-09T17:46:13","slug":"gamma-gamma-coincidence","status":"publish","type":"page","link":"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/experiments\/gamma-gamma-coincidence\/","title":{"rendered":"Gamma-Gamma Coincidence"},"content":{"rendered":"\n<p class=\"has-text-align-center\"><em>Author: Tim<\/em><\/p>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<p>I have waited 25 years to perform this experiment.  All I needed was a second ORTEC ScintiPack to execute it.  Well, not really, but the recent eBay opportunity to get a second ScintiPack sure made it easy&#8230;  I had everything else waiting for it&#8217;s arrival.<\/p>\n\n\n\n<p>This experiment exploits the gamma-gamma coincidence of two gammas that (nearly) accompany every <sup>60<\/sup>Co decay. 99.85% of <sup>60<\/sup>Co ends up in an excited state of <sup>60<\/sup>Ni, that with a half-life of 300fs which decays with 1173keV gamma ray to a lower, but yet another, excited state, which in-turn decays to the <sup>60<\/sup>Ni ground state with a half-life of 713fs with the emission of a 1332.5keV gamma ray.  The relatively short times between these transitions makes it seem that they both are emitted simultaneously, and justifiably so, since the timing between the two emissions is typically under a picosecond!  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nucleide.org\/DDEP_WG\/Nuclides\/Co-60_tables.pdf\"><img loading=\"lazy\" width=\"1336\" height=\"1462\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Screen-Shot-2020-04-09-at-12.55.52-AM.png\" alt=\"\" class=\"wp-image-2959\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Screen-Shot-2020-04-09-at-12.55.52-AM.png 1336w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Screen-Shot-2020-04-09-at-12.55.52-AM-768x840.png 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Screen-Shot-2020-04-09-at-12.55.52-AM-247x270.png 247w\" sizes=\"(max-width: 1336px) 100vw, 1336px\" \/><\/a><\/figure>\n\n\n\n<p><sup>60<\/sup>Co is the standard by which all gamma ray spectroscopy systems are measured and calibrated against.  Specifically, the 1332.5keV line is the line that all systems compare their performance by. Gamma ray spectroscopists, both professional and amateur alike, can draw the <sup>60<\/sup>Co gamma spectrum from memory &#8211; the twin pillars of 1173keV and 1332.5KeV, and their combined Compton Scattering tail.<br><br>This experiment aims to splits up the pair through a bit of selfless promotion by their twin; one sibling photon takes the back stage in order to let the other photon shine all its own.  This goes both ways&#8230;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1.jpg\" alt=\"\" class=\"wp-image-2964\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_1-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>The Co-60 all spectroscopist are familiar with, gamma lines at 1173 and 1333keV.<\/figcaption><\/figure>\n\n\n\n<p>The concept is simple.  You need two detectors that operate in coincidence, where one plays the role of the tigger detector from one of the two gamma rays, while the other detector measures the energy of the second gamma ray.  The trigger detector must also have the ability to measure the energy, but it&#8217;s energy information is turned into a simple digital logic signal that says &#8220;go\/no-go.&#8221;  The trigger detector can be set (through a single channel analyzer, SCA) to only register an event of just the right energy. If the gamma ray energy is too low, or too high it is ignored, but if it falls within a preset energy window, it is registered.  Similarly, a digital signal can be generated from the full energy range detector if an event of any amplitude occurs. If the two digital signals occur simultaneously (within a 100ns window in this case) then we can declare a coincidence event, having individually captured the two gamma rays in our two detectors from a single <sup>60<\/sup>Co decay.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934.jpg\"><img loading=\"lazy\" width=\"3598\" height=\"2698\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934.jpg\" alt=\"\" class=\"wp-image-2960\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934.jpg 3598w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4934-360x270.jpg 360w\" sizes=\"(max-width: 3598px) 100vw, 3598px\" \/><\/a><figcaption>Two 2&#215;2-inch NaI(Tl) detectectors, their HV and preamp bases as well as external direct anode coupling preamps.<\/figcaption><\/figure>\n\n\n\n<p>I use two 2&#215;2-inch NaI(Tl) detectors oppositely facing each other with a small exempt quantity <sup>60<\/sup>Co source centered between them. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957.jpg\" alt=\"\" class=\"wp-image-2961\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4957-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>Yellow and blue traces show coincident events from both NaI(Tl) detectors.  Time scale is 1us\/div.<\/figcaption><\/figure>\n\n\n\n<p>Let&#8217;s make the conditions for triggering, and hence coincidence, a bit more specific.  If there are two simultaneous gamma rays of discrete and separate energies from each <sup>60<\/sup>Co decay, then triggering on only one of specific energies in the trigger detector, means the second detector&#8217;s simultaneous event must be from encountering the other energy gamma ray.  This is where one twin lets the other shine.  By this energy specific energy trigger, only the other gamma ray energy can enter the detector that the spectroscopic data will be derived from, effectively eliminating one of the two paired gamma rays from the spectra.  Each energy photon (photopeak in detector language) can take their turn being the trigger energy.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6.jpg\" alt=\"\" class=\"wp-image-2965\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_6-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>Red vertical lines show the energy &#8220;window&#8221; settings, inside of which are the permitted trigger photon energies, so they should not appear in the resulting spectrum.<\/figcaption><\/figure>\n\n\n\n<p>The next challenge are the electronics, getting two parallel paths of equal gain and control over timing is a bit tedious.  It can all be done in a single standard NIM crate. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932.jpg\" alt=\"\" class=\"wp-image-2958\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4932-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>NIM module electronics layout.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-rotated.jpg\" alt=\"\" class=\"wp-image-2977\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4783-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>The single NIM crate of modules needed to accomplish this experiment.<\/figcaption><\/figure>\n\n\n\n<p>A timing delay is needed to permit the coincidence circuitry to generate a &#8220;gating&#8221; pulse. So the energy resolving detector signal is delay by 2.5us.  Note in the image below, the varied pulse heights of the energy resolving detector, as it is seeing the entire energy spectrum, while the trigger detector&#8217;s pulse height is narrowly selecting the same pulse height (centered on one of the two photopeaks).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942.jpg\" alt=\"\" class=\"wp-image-2962\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4942-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>Signal of full range energy detector is delayed by 2.5us. <\/figcaption><\/figure>\n\n\n\n<p>The gate signal is adjusted such that its delay and width are set to bracket the positive going portion of the spectroscopy amplifiers output.  Only when the gate (green trace) is in a high state will the MCA will be active.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939.jpg\" alt=\"\" class=\"wp-image-2963\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_4939-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>Trigger event (yellow trace) in coincidence with an event of any energy (blue trace) and the &#8220;gate&#8221; signal to the MCSA show in green.<\/figcaption><\/figure>\n\n\n\n<p>The following is the result of a gathered spectrum, the red lines show the energy selective window bracketing the 1173keV photo peak, and note how it is not there.  The 1173 Compton tail is also not present, and this spectrum is solely that of the 1332.5keV line.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7.jpg\" alt=\"\" class=\"wp-image-2969\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_7-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>The first spectrum, set to trigger on the 1173keV photopeak, enables the isolated collection of the 1332.5keV peak and its Compton continuum.  Red vertical lines showing the window of trigger energy acceptance, bracketing the 1173keV.  <\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3.jpg\" alt=\"\" class=\"wp-image-2966\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_3-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>The first spectrum, set to trigger on the 1173keV photopeak, enables the isolated collection of the 1332.5keV peak and its Compton continuum. <\/figcaption><\/figure>\n\n\n\n<p>We simply change the energy selective window to bracket the 1332.5keV line and the 1173keV spectrum appears by itself.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2.jpg\" alt=\"\" class=\"wp-image-2967\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_2-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>Flipping the energy criteria to trigger on the 1332.5keV photopeak, resulting in isolating the 1173keV line.<\/figcaption><\/figure>\n\n\n\n<p>How did we do?  We can compare the two isolated spectra with a standard non-gated <sup>60<\/sup>Co gamma spectrum and we see that both the energies line up as well as a reduced Compton tail.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4.jpg\" alt=\"\" class=\"wp-image-2968\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_4-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>Comparison of the two isolated peaks with a normal Co-60 spectra.  <\/figcaption><\/figure>\n\n\n\n<p>Does it all add up?  Let simply take the date from the above plot and add them together and compare to the non-gated normal <sup>60<\/sup>Co spectrum.  Almost a perfect match! I do not understand why the 200keV line is so high for the 1332.5keV spectrum.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5.jpg\"><img loading=\"lazy\" width=\"4667\" height=\"3500\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5.jpg\" alt=\"\" class=\"wp-image-2970\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5.jpg 4667w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Fig_5-360x270.jpg 360w\" sizes=\"(max-width: 4667px) 100vw, 4667px\" \/><\/a><figcaption>Adding the two isolate spectra together, and then comparing to the normal Co60 spectra.  A near perfect fit.  (although I do not yet understand the large increase in low energy line at about 200keV for the 1332.5keV isolated spectrum)<\/figcaption><\/figure>\n\n\n\n<p>It took 25 years to get a second ScintiPack and a week of patient coincidence counting, and we can call this one a success!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Author: Tim I have waited 25 years to perform this experiment. All I needed was a second ORTEC ScintiPack to execute it. Well, not really, but the recent eBay opportunity to get a second ScintiPack sure made it easy&#8230; I had everything else waiting for it&#8217;s arrival. This experiment exploits the gamma-gamma coincidence of&#8230;<\/p>\n<p class=\"read-more\"><a class=\"btn btn-default\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/experiments\/gamma-gamma-coincidence\/\"> Read More<span class=\"screen-reader-text\">  Read More<\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":2962,"parent":545,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"categories":[31,86,18,37],"tags":[],"_links":{"self":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2955"}],"collection":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/comments?post=2955"}],"version-history":[{"count":10,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2955\/revisions"}],"predecessor-version":[{"id":2982,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2955\/revisions\/2982"}],"up":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/545"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media\/2962"}],"wp:attachment":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media?parent=2955"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/categories?post=2955"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/tags?post=2955"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}