{"id":2766,"date":"2020-03-24T16:31:08","date_gmt":"2020-03-24T20:31:08","guid":{"rendered":"http:\/\/www.nuclearphysicslab.com\/npl\/?page_id=2766"},"modified":"2020-03-26T13:41:03","modified_gmt":"2020-03-26T17:41:03","slug":"refurbishment-of-ln2-dewars","status":"publish","type":"page","link":"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/","title":{"rendered":"Refurbishment of LN2 Dewars"},"content":{"rendered":"\n<p class=\"has-text-align-center\">Author: Jay Howson<br>Date: 3\/15\/2020<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_33_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\">Quick Links<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" style=\"display: none;\"><label for=\"item\" aria-label=\"Table of Content\"><i class=\"ez-toc-glyphicon ez-toc-icon-toggle\"><\/i><\/label><input type=\"checkbox\" id=\"item\"><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1'><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Intro\" title=\"Intro\">Intro<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#How_LN2_Dewars_Work\" title=\"How LN2 Dewars Work\">How LN2 Dewars Work<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#The_Conundrum\" title=\"The Conundrum\">The Conundrum<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#A_DIY_Valve_Adaptor_Solution\" title=\"A DIY Valve Adaptor Solution\">A DIY Valve Adaptor Solution<\/a><ul class='ez-toc-list-level-4'><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Flange_Adaptor\" title=\"Flange Adaptor\">Flange Adaptor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Vacuum_Hardware\" title=\"Vacuum Hardware\">Vacuum Hardware<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Linear_Actuator\" title=\"Linear Actuator\">Linear Actuator<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Initial_Pump_Down\" title=\"Initial Pump Down\">Initial Pump Down<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/#Ongoing_Work\" title=\"Ongoing Work\">Ongoing Work<\/a><\/li><\/ul><\/nav><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Intro\"><\/span>Intro<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I was gifted a trio of LN2 (liquid nitrogen) dewars which had lost their vacuum (to an unacceptable degree) for one reason or another, probably a combination of age, the valve, perhaps a microcrack in a weld or two. Not really sure.  I decided to try and refurbish them, such that I could utilize for an HPGe system. Even if I have to re-pump the vacuum once a year, that is completely manageable. We will see how it goes. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" width=\"2288\" height=\"3195\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399.jpg\" alt=\"\" class=\"wp-image-2788\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399.jpg 2288w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399-1790x2500.jpg 1790w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399-768x1072.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399-1100x1536.jpg 1100w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399-1467x2048.jpg 1467w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Bad_Canberra_Dewar-e1585088389399-193x270.jpg 193w\" sizes=\"(max-width: 2288px) 100vw, 2288px\" \/><figcaption>A Bad Canberra Dewar<\/figcaption><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<h3><span class=\"ez-toc-section\" id=\"How_LN2_Dewars_Work\"><\/span>How LN2 Dewars Work<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The way LN2 dewars work to keep the liquid nitrogen cold, is by using a vacuum as an insulator between 2 vessels. The level of vacuum isn&#8217;t terribly deep, typically in the double digit mTorr range (correct me if I am wrong on that). <\/p>\n\n\n\n<p>The vacuum is aided by a fibrous insulation attached to the exterior circumference of the inner vessel. You might think this insulation behaves like the insulation within your homes walls, but in fact the fiberglass home insulation works by slowing down the motion of air in the walls, thus reducing thermal transfer thru that medium.<\/p>\n\n\n\n<p> This fibrous insulation works in vacuum, thus there is very little air to slow down thermal transfer within. Instead this insulation cools down with the inner vessel when the LN2 is added. Being fibrous, the insulation&#8217;s surface area to mass ratio is extremely high; this has the effect to providing a massive cold surface area within the vacuum. Acting very much like a cryo-pump the insulation absorbs any contaminants further reduces the pressure within the interstitial volume of the dewar, increasing the ability to provide thermal insulation. <\/p>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<h3><span class=\"ez-toc-section\" id=\"The_Conundrum\"><\/span>The Conundrum<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>In order to service the vacuum on a dewar you need a special adapter which provides a seal around the dewars port. while simultaneously providing a threaded linear actuator enabling the operator to remove a gasket-ed plug that seals the port. <\/p>\n\n\n\n<p>This device is called a valve adapter. Unfortunately they are very expensive. I was quoted $900 for one that adapts to a 5\/8&#8243; port. And I had 3 different port sizes on my dewars. (a problem with dewars, the manufacturers can&#8217;t seem to make up their minds on what port style they want) <br><br>I however have a reasonable assortment of vacuum components. A pair of Wilson seals, one around the port and one around an actuator rod. Would provide an ideal way to make my own valve adapter. Unfortunately the outer diameters of the 3 ports were all sizes I did not have a Wilson seal for. They are fairly hard to locate of ebay, and buying 3 different sized Wilson seals new would also cost hundreds of dollars. <br><br>I was able to locate a 5\/8&#8243; seal for 15 bucks which fits on the smallest port. But the other two were far larger (1-3\/16 and 1-3\/8). <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-medium is-resized\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port.jpg\"><img loading=\"lazy\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-1875x2500.jpg\" alt=\"\" class=\"wp-image-2787\" width=\"469\" height=\"625\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/1-3_8-Pumpout-Port-203x270.jpg 203w\" sizes=\"(max-width: 469px) 100vw, 469px\" \/><\/a><figcaption>A  Pumpout Port as Received, yea we are gonna have to clean that&#8230; <\/figcaption><\/figure><\/div>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<h3><span class=\"ez-toc-section\" id=\"A_DIY_Valve_Adaptor_Solution\"><\/span>A DIY Valve Adaptor Solution<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I eventually decided that I was going to be the only person ever servicing these dewars, I intend to use them for quite some time, and have no plans to resell. Thus a little modification to the dewar wasn&#8217;t going to hurt anyone.<\/p>\n\n\n\n<h4><span class=\"ez-toc-section\" id=\"Flange_Adaptor\"><\/span>Flange Adaptor<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>I fortuitously procured 2 KF40 blank studs from LDS Vacuum when they were on sale, and proceeded to bore them out to 1-3\/16&#8243; and 1-3\/8&#8243;. I also procured some Torr-Seal equivalent epoxy when it too was on sale. Slathering up the dewars valve stem and slipping the KF40 was easy enough, some alcohol was used to clean things up a bit and it was left to cure. <\/p>\n\n\n\n<div class=\"wp-container-3 wp-block-columns\">\n<div class=\"wp-container-1 wp-block-column\">\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472.jpg\" alt=\"\" class=\"wp-image-2774\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKF40-rotated-e1585084894472-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>KF40 studs, 1 machined<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-container-2 wp-block-column\">\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2.jpg\" alt=\"\" class=\"wp-image-2775\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DewarKf40_2-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Fit Check prior to cleaning and epoxying<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>I&#8217;ll get a picture of it epoxied in place once I take it off the Dewar. <\/p>\n\n\n\n<h4><span class=\"ez-toc-section\" id=\"Vacuum_Hardware\"><\/span>Vacuum Hardware<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>My 5\/8&#8243; wilson seal sat on a KF16 flange. This sizing is only important because a KF25 would not fit alongside the stem of an HPGe I also intend to refurbish the vacuum on at some point in the future, I wanted this assembly to be compatible with all my refurbishment projects. <\/p>\n\n\n\n<p> I have a 4 way cross connected to a 3 way Tee. The gauges sit on one leg of the cross, and are a pirani gauge and a cold cathode penning gauge. Together they can read from ATM to 10^-8 torr or so. The piston travels thru the 4 way cross, with the vacuum being pulled thru my turbo pump on the the bottom. <br><br>I thoroughly cleaned all the parts with alcohol prior to assembly, and pumped on it with the turbo for 3-4 days before even attempting to actuate the valve. The last thing I want is moisture to get inside the dewars interstitial volume, and my garage is very humid this time of year. (its also been raining a lot lately.)<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor.jpg\" alt=\"\" class=\"wp-image-2814\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/DIY-valve-adaptor-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Hardware rev2,  with the penning gauge attached<\/figcaption><\/figure>\n\n\n\n<h4><span class=\"ez-toc-section\" id=\"Linear_Actuator\"><\/span>Linear Actuator<span class=\"ez-toc-section-end\"><\/span><\/h4>\n\n\n\n<p>My linear actuator is a 1\/2&#8243; precision ground rod of tooling steel fit with a 1\/2&#8243; Wilson seal on a KF16. A 1\/2&#8243; rod fits nicely into the 5\/8&#8243; bore of the KF16 parts with moderate clearance around it for gas movement. A driving point at using 1\/2&#8243; rod, was the 3\/8-16 thread requirement for the 1-3\/8&#8243; valve. I bored both ends of the rod, and drilled holes for 1\/4-20 (1-3\/16 valve),  8-32 (5\/8&#8243; valve), and 3\/8-16 (1-3\/8&#8243; valve).  The 8-32 threads are nested inside the 3\/8-16 threads. Once again enabling me to use this one piston for all 3 of my dewars valves. <\/p>\n\n\n\n<p> I placed a shroud of PVC pipe around it to act both as a dust cover and provide something for my bolt and nut to push against. The nut turns on the bolt which is threaded into the back of the rod. By turning the nut, I apply pressure to the pipe, which causes the bolt to pull the piston outward. After initial application of force via the nuts rotation the valve opens and will move more freely by hand. I position the valve plug to be between both the valve and the conical KF40-KF16 adaptor. In retrospect a KF40 nipple about 2-3 inches long would be ideal for this location.  Enabling better gas flow around the plug in this space. I will have to keep my eyes peeled for one on ebay. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston.jpg\" alt=\"\" class=\"wp-image-2816\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Piston-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Linear actuator piston with adjustment threads and dust protector<\/figcaption><\/figure>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<h3><span class=\"ez-toc-section\" id=\"Initial_Pump_Down\"><\/span>Initial Pump Down<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Initial pump down consisted of trying to pump contaminants out of the adapter assembly, moisture etc. In a perfect world I would have a cryo-trap; but meh. <\/p>\n\n\n\n<p>I Pumped on it for several days with the turbo running, and discovered I had a slow leak; about 1\/10th of a mtorr per 20 seconds. Probably a spec of dust on an o-ring, my garage isn&#8217;t the cleanest. I took everything apart and applied vacuum grease to my o-rings. then pumped for 3-4 days to remove as much moisture as I could. I even took a hair dryer to every inch of the assembly to drive out more moisture. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1.jpg\" alt=\"\" class=\"wp-image-2773\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Assembly_attached_1-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>During Initial Pump down of the valve adapter assembly (Dewar still closed) I have not yet fabricated the adjustment mechanism which will fit over the piston like a shroud and allow fine motion control of the piston.  <\/figcaption><\/figure>\n\n\n\n<div class=\"wp-container-6 wp-block-columns\">\n<div class=\"wp-container-4 wp-block-column\">\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure.jpg\" alt=\"\" class=\"wp-image-2815\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/Initial-pressure-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Vacuum on the gauge just after cracking the dewars port<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-container-5 wp-block-column\">\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while.jpg\" alt=\"\" class=\"wp-image-2813\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/After-pumping-for-a-while-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Vacuum after pumping for 3-4 hours with the turbo<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>The initial pump out of the vessel is the most critical portion of the exercise. I began by turning off the turbo and waiting for it to spool down. I closed off my roughing pumps valve and I slowly rotated my actuator nut, barely cracking open the  dewar. Observing  the vacuum slowly rise from ~6mtorr to ~4.1 torr, it took a while to level off, and you want it to. <\/p>\n\n\n\n<p>One key detail that needs to be followed here, is that you don&#8217;t want to suddenly change the vacuum in a dewar. All that insulator material we were discussing earlier. If you suddenly apply vacuum and the internal pressure is high the rushing of gas out of its fibrous structure will cause it to expand, which would be bad. Like wise, if you suddenly return to ATM, it will compress the fibers, which is also bad. Not damaging the fibers is important, so I performed my initial observation of the internal pressure very slowly. <\/p>\n\n\n\n<p>I discovered that the internal pressure was low enough, that doing things slowly probably didn&#8217;t matter. But if I had been at ATM, or base pressure (which it wasn&#8217;t, cause I knew it was bad) it would have been worth the extra effort. <\/p>\n\n\n\n<p>The ideal range for dewars vacuum level is apparently open for debate to the casual google surfer. I saw 1mtorr to 100mtorr quoted as being good enough. I am simply going to shoot for as low as I can get, in say a weeks worth of pumping and call it good.<\/p>\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n\n<h3><span class=\"ez-toc-section\" id=\"Ongoing_Work\"><\/span>Ongoing Work<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>I will pump on the open dewar for several days, and then use a hair dryer  to heat the internal volume of the Dewar and a space heater on the outside for a few hours. Driving off contaminants stuck to the internal surfaces of the interstitial volume. More importantly some of that heat will transfer to the fibrous insulation and drive more contaminants out of its massive surface area. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Author: Jay HowsonDate: 3\/15\/2020 Intro I was gifted a trio of LN2 (liquid nitrogen) dewars which had lost their vacuum (to an unacceptable degree) for one reason or another, probably a combination of age, the valve, perhaps a microcrack in a weld or two. Not really sure. I decided to try and refurbish them,&#8230;<\/p>\n<p class=\"read-more\"><a class=\"btn btn-default\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/refurbishment-of-ln2-dewars\/\"> Read More<span class=\"screen-reader-text\">  Read More<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":2788,"parent":122,"menu_order":1,"comment_status":"open","ping_status":"closed","template":"","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"categories":[34,3,47],"tags":[],"_links":{"self":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2766"}],"collection":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/comments?post=2766"}],"version-history":[{"count":26,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2766\/revisions"}],"predecessor-version":[{"id":2832,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/2766\/revisions\/2832"}],"up":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/122"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media\/2788"}],"wp:attachment":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media?parent=2766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/categories?post=2766"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/tags?post=2766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}