{"id":1258,"date":"2020-03-12T19:53:54","date_gmt":"2020-03-12T23:53:46","guid":{"rendered":"http:\/\/www.nuclearphysicslab.com\/npl\/?page_id=1258"},"modified":"2020-03-17T23:07:23","modified_gmt":"2020-03-18T03:07:23","slug":"resurrecting-an-antique-mca","status":"publish","type":"page","link":"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/resurrecting-an-antique-mca\/","title":{"rendered":"Antique MCA"},"content":{"rendered":"\n<p>A friend gave Tim this old MCA that was disused and about to be discarded.  Tim took it on as a winter project and enlisted the help of the group one by one.  This is a real museum piece from the late 1960.  It has a conversion gain of 256 channels and uses *volatile* core memory.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943.jpg\" alt=\"\" class=\"wp-image-1259\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7943-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>The refurbished MCA displaying a 137Cs NaI gathered spectrum.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-rotated.jpg\" alt=\"\" class=\"wp-image-1262\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7983-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>The core memory board.  Luckily this was still in-tact.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-rotated.jpg\" alt=\"\" class=\"wp-image-1263\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7986-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054.jpg\" alt=\"\" class=\"wp-image-1264\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054-500x500.jpg 500w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054-768x768.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054-1536x1536.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054-2048x2048.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8054-270x270.jpg 270w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>The pulses from the spectroscopy amplified as seen on a period correct, Tek 547 Oscilloscope.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368.jpg\" alt=\"\" class=\"wp-image-1266\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8368-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>The MCA actually had a digital output to drive a teletype at ~110 baud.  The output circuitry was modified to output RS-232 at 1200 baud.  But, one of the RS-232 bits was locked high.  It just dumped the data one way, there is no handshaking.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-rotated.jpg\" alt=\"\" class=\"wp-image-1265\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8363-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Baud rate was confirmed with my inline RS232 protocol analyzer.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-rotated.jpg\" alt=\"\" class=\"wp-image-1268\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8625-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><figcaption>We had to trouble shoot the modified communication board, which was deeply nested in the unit. To make matters a bit more challenging, the home-made data lines were all purple without any other form of labeling&#8230; (be kind to the next person, even if it is 5 decades later) <\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433.jpg\" alt=\"\" class=\"wp-image-1267\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8433-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>Using an oscilloscope with infinite persistence on, one can see that the 7th bit is alway high. <\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-rotated.jpg\" alt=\"\" class=\"wp-image-1269\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8636-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>A bit of surgery and we have all bits talking&#8230;<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-rotated.jpg\" alt=\"\" class=\"wp-image-1273\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8787-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>To be cute, I started it out, carried on a bit by Brother Lou, then Jimbo, and Brian, we wrote a little HP Basic code on the HP85B to listen for the RS232 dump, save the data, and plot the spectrum both on the CRT and make a hard copy to the thermal printer.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714.jpg\" alt=\"\" class=\"wp-image-1272\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8714-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702.jpg\" alt=\"\" class=\"wp-image-1275\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8702-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>Nice 137Cs spectrum.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701.jpg\" alt=\"\" class=\"wp-image-1271\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8701-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-rotated.jpg\" alt=\"\" class=\"wp-image-1270\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8688-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Looks about the same.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800.jpg\" alt=\"\" class=\"wp-image-1276\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800-500x500.jpg 500w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800-768x768.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800-1536x1536.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800-2048x2048.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_8800-270x270.jpg 270w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-rotated.jpg\"><img loading=\"lazy\" width=\"3024\" height=\"4032\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-rotated.jpg\" alt=\"\" class=\"wp-image-1277\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-rotated.jpg 3024w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-1875x2500.jpg 1875w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-768x1024.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-1152x1536.jpg 1152w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-1536x2048.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_9452-203x270.jpg 203w\" sizes=\"(max-width: 3024px) 100vw, 3024px\" \/><\/a><figcaption>Mounted it all up in a small relay rack.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801.jpg\"><img loading=\"lazy\" width=\"4256\" height=\"2832\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801.jpg\" alt=\"\" class=\"wp-image-1278\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801.jpg 4256w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801-768x511.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801-1536x1022.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801-2048x1363.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/TIM_6801-406x270.jpg 406w\" sizes=\"(max-width: 4256px) 100vw, 4256px\" \/><\/a><figcaption>The complete 1960&#8217;s dream nuclear spectroscopy lab! (thought the HP85B was from the 70s)<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947.jpg\"><img loading=\"lazy\" width=\"4032\" height=\"3024\" src=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947.jpg\" alt=\"\" class=\"wp-image-1279\" srcset=\"http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947.jpg 4032w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947-768x576.jpg 768w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947-1536x1152.jpg 1536w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947-2048x1536.jpg 2048w, http:\/\/www.nuclearphysicslab.com\/npl\/wp-content\/uploads\/IMG_7947-360x270.jpg 360w\" sizes=\"(max-width: 4032px) 100vw, 4032px\" \/><\/a><figcaption>We end with a 60Co spectrum.<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>A friend gave Tim this old MCA that was disused and about to be discarded. Tim took it on as a winter project and enlisted the help of the group one by one. This is a real museum piece from the late 1960. It has a conversion gain of 256 channels and uses *volatile*&#8230;<\/p>\n<p class=\"read-more\"><a class=\"btn btn-default\" href=\"http:\/\/www.nuclearphysicslab.com\/npl\/npl-home\/spectroscopy\/software_and_hardware\/resurrecting-an-antique-mca\/\"> Read More<span class=\"screen-reader-text\">  Read More<\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":1259,"parent":122,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":{"advanced-sidebar-menu\/link-title":"","advanced-sidebar-menu\/exclude-page":false},"categories":[61,3,47,37],"tags":[],"_links":{"self":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/1258"}],"collection":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/comments?post=1258"}],"version-history":[{"count":4,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/1258\/revisions"}],"predecessor-version":[{"id":2001,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/1258\/revisions\/2001"}],"up":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/pages\/122"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media\/1259"}],"wp:attachment":[{"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/media?parent=1258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/categories?post=1258"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.nuclearphysicslab.com\/npl\/wp-json\/wp\/v2\/tags?post=1258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}